Calculate the battery in your solar installation based on daily consumption, days of autonomy and depth of discharge. The result indicates the required usable and nominal capacity, the ampere-hours at system voltage, and how many modules would be required for Pylontech, Pytes, ZYC or Victron.
Consumption figures
How to interpret the result
- Range: For off-grid use, 2 days are usually sufficient in the south-east of the peninsula; in the north or in winter, 3 days. For self-consumption with grid connection, it is sufficient to cover the night (1 day).
- Night-time consumption: If you’re not aware, it’s between 35 and 50 % of daily consumption in a main residence. You can view this on an hourly basis using your bill and your energy supplier’s app.
- Power, not just energy: As well as kWh, the battery must be able to supply the amperage required by the inverter. Each 5 kWh module delivers 50–100 A; for inverters of 5 kW or more, install at least two.
- Tension: For inverters of 3 kW or more, a 48 V system is recommended: lower current, thinner cables and more battery options.
Related guides: Pytes V5 vs Pylontech US5000, Configure Victron ESS y DVCC.