Maxge Alpha+ 1P+N circuit breaker, 40A, C-curve, 6kA

2,53€

TAXES INC.
  • Poles: 1P+N
  • Operating voltage: 240V AC
  • Rated current: 40 amps
  • Firing curve: C
  • Breaking capacity: 6kA
  • International standard EN/IEC 60898-1
  • Local status signalling
  • Window for circuit marker
  • Dimensions: 36mm (18mm per pole)
  • Terminal connection for copper cables: up to 25 mm² flexible / 35 mm² rigid
  • Insulation voltage (Ui) 500 V
  • Impulse voltage (Uimp) 4kV
  • Pollution degree 3
  • Double insulation class 2
  • Suitable for sectioning
  • Working temperature: -5 °C to +40 °C
  • Non-accessoriable (except padlockable)
- +
Disponible para la venta · Plazo de entrega según stock de la referencia
Product
Finance your purchase with Cetelem
Reference: EPB63ME1NC40 Categories: ,

Details of the Maxge Alpha+ 1P+N circuit breaker, 40A, C-curve, 6kA

Maxge Alpha+ 1P+N circuit breaker, 40A, C-curve, 6kA – EPB63ME1NC40

The Maxge Alpha+ 1P+N circuit breaker, 40A, C-curve. 6kA is a circuit breaker from the Maxge Alpha+ residential range, designed to protect single-phase circuits simply, reliably and cost-effectively against overloads and short circuits.

In a 1P+N configuration (protected phase and isolated neutral), with a rated current of 40 A, a C-triggering curve and a breaking capacity of 6 kA, this is the standard circuit breaker found in domestic and small commercial distribution boards: lighting, sockets, kitchen appliances, air conditioning or charging and self-consumption circuits, depending on the rating.

It combines thermal and magnetic protection in a single unit and cuts off the circuit when it detects an overcurrent, preventing damage to the wiring and connected loads.

Technical specifications

  • Poles: 1P+N
  • Operating voltage: 240V AC
  • Rated current: 40 amps
  • Firing curve: C
  • Breaking capacity: 6kA
  • International standard EN/IEC 60898-1
  • Local status signalling
  • Window for circuit marker
  • Dimensions: 36mm (18mm per pole)
  • Terminal connection for copper cables: up to 25 mm² flexible / 35 mm² rigid
  • Insulation voltage (Ui) 500 V
  • Impulse voltage (Uimp) 4kV
  • Pollution degree 3
  • Double insulation class 2
  • Suitable for sectioning
  • Working temperature: -5 °C to +40 °C
  • Non-accessoriable (except padlockable)

Applications

Main and secondary distribution boards for residential properties, commercial premises and offices, and protection of the AC output from single-phase photovoltaic inverters for self-consumption, selecting the rating according to the cable cross-section and the maximum current of the equipment.

Weight and dimensions

Weight 0,2 kg
Dimensions 6,66 × 3,6 × 7,8 cm

User feedback

Reviews

There are no reviews yet.

Be the first to review “Magnetotermico Maxge Alpha+ 1P+N, 40A, curva C. 6kA”

Your email address will not be published. Required fields are marked *

Delivery deadlines

At FVComponentes.com we have stock of the references with the highest turnover, however our catalogue is so wide and economical because we work with many of the references on request. This means that the usual delivery time of 2-4 working days can be extended to 1-2 weeks + subsequent shipment by us. Thanks to this, we can offer very competitive and attractive prices to our customers that are difficult to match. If you wish, you can write to us via the chat on the website, call us at 968 97 83 01 or write to us at comercial@fvcomponentes.com to check if we have stock or the delivery time of the component you wish to purchase before finalising your order.