You must be logged in to post a review.
- Free shipping to mainland Spain for orders over 300€.
69,44€
Direct current and 48V cut-off capacity: 80 A
Current consumption when open: 4 mA
Protection category: IP54
Victron Cyrix-Li-Charge 24/48V-120A battery combiner - CYR020120430: prevents undervoltage, overvoltage and overtemperature of the cells.
In the field of LiFePO4 batteries, a fundamental safeguard is cell balancing, an essential practice for maintaining battery performance. In the case of Victron LiFePO4 batteries, cell balancing is fully incorporated, thus laying the foundation for safe and prolonged operation.
However, protection does not stop there. A second line of defence is erected, consisting of additional safeguard measures:
Within this scenario, the VE.Bus BMS (Battery Management System) stands as the core of this second line of safeguard. However, it is important to note that not all loads or charging devices can be directly controlled by the VE.Bus BMS.
To address this need, Cyrix switches come into play, a versatile solution that can be controlled by the VE.Bus BMS for effective disconnection of loads or chargers that would otherwise not be directly managed.
In conclusion, the combination of cell balancing and the robust performance of the VE.Bus BMS constitutes a comprehensive protection system for Victron LiFePO4 batteries. This strategy ensures not only efficient operation, but also long battery life, thus supporting the reliability and durability of these energy storage systems.
The Cyrix-Li-Charge will connect a battery charger after 3 seconds:
- If the disconnection output of the VE.Bus BMS charger is high.
- If 13.0 V (26.0 V or 52.0 V resp.) or more reaches its connection terminal of the battery charger.
- And if 2 V or more arrive at its battery terminal (the Cyrix will remain open if it is not connected to the battery).
The Cyrix-Li-Charge will disconnect immediately when its control input becomes floating, indicating an overvoltage or overtemperature of the cells.
In general, the overvoltage alarm on the cells will reset shortly after charging stops. The Cyrix will then reconnect the charger after a delay of 3 seconds. When the Cyrix-Li-Charge is activated (charger connected to the battery) it will deactivate after 1 hour to check if the charger is still enabled. If after the Cyrix has been deactivated, the output of the battery charger is immediately increased to 13.0 V or more, the Cyrix will reactivate with a delay of 3 seconds.
Note: In case of zero discharge current, or low discharge current, the Cyrix will not be deactivated shortly after the charger has been switched off and/or disconnected, because the battery voltage will remain above 13.5V.
View Victron Cyrix-Li-Charge 24/48V-120A battery combiner datasheet - CYR020120430
Weight | 1 kg |
---|---|
Dimensions | 8 × 4,6 × 4,6 cm |
You must be logged in to post a review.
Online shop specialising in Victron Energy with the best prices on solar panels and lithium batteries.
Official Fronius and Victron Energy technical service.
Do you need assembly? Installation of solar panels
At FVComponents.com we have stock of the references with the highest turnover, however our catalogue is so wide and economical because we work with many of the references on request. This means that the usual delivery time of 2-4 working days can be extended to 1-2 weeks + subsequent shipment by us. Thanks to this, we can offer very competitive and attractive prices to our customers that are difficult to match. If you wish, you can write to us via the chat on the website, call us at 968 97 83 01 or write to us at [email protected] to check if we have stock or the delivery time of the component you wish to purchase before finalising your order.
Reviews
There are no reviews yet.