BlueSolar Victron PWM-LCD and USB 12/24V-10A controller - SCC010010050

24,41

TAXES INC.

Battery voltage: 12/24V with automatic input voltage detection
Rated load current: 10A
Automatic load disconnection: Yes
Weight (kg): 0,15
Dimensions (mm): 96 x 169 x 36 mm

- +
Product available for sale
Finance your purchase with Cetelem
Reference: SCC010010050 Categories: ,

Details of the BlueSolar Victron PWM-LCD and USB 12/24V-10A controller - SCC010010050

BlueSolar Victron PWM-LCD and USB 12/24V-10A controller - SCC010010050

  • Liquid crystal display: Allows monitoring and configuration of the equipment.
  • Charging output: To prevent the battery from over-discharging, connect all loads to the charging output. This output disconnects the load when the battery has discharged to a preset voltage. Some loads (especially inverters) are best connected directly to the battery, and the inverter remote control to the load output. The connection and disconnection voltages are adjustable.
  • Day/night programming of the load output: This option allows you to pre-set the ON-time after twilight.
  • Programmable battery charging algorithm: Pre-programmed algorithms for AGM, GEL, flooded or LiFePO4 batteries (only those with internal BMS).
  • Two 5-volt USB outputs: Maximum current (both outputs together): 2A

BlueSolar Victron PWM-LCD and USB 12/24V-10A BlueSolar PWM-LCD Controller Specifications

  • Battery voltage:  12/24 V with automatic detection of the input voltage
  • Rated load current: 10A
  • Automatic disconnection of loads: Yes
  • Maximum solar voltage: 28V / 55V
  • Self-consumption: < 10 mA
  • Charging output: Manual control + undervoltage cut-off + timer
  • Protection:
    • Reversal of battery polarity (fuse)
    • Output short-circuit
    • Overtemperature
  • Overload protection:
    • Switch-off after 60 s in case of reaching the load 130%
    • Shutdown after 5 s if the load 160% is reached
    • Immediate disconnection in case of short-circuit
  • Grounding: Common positive
  • Operating temp. range: -35 to +60°C (full load)
  • Humidity (non-condensing): Max. 95%

Battery

  • Absorption" charging voltage: Factory setting: 14,4V / 28,8V
  • Float" loading voltage: Factory setting: 13.7V / 27.4V
  • Load disconnection due to low voltage: Factory setting: 11.2V / 22.4V
  • Load reconnection due to low voltage: Factory setting: 12,6V / 25,2

Installation of the BlueSolar Victron PWM-LCD and USB 12/24V-10A Controller

First of all, the batteries must be connected so that the controller recognises the system voltage. Use 12V solar panels (36 cells) for 12V systems and 24V solar panels (72 cells) for 24V systems.

Steps to be taken:

  1. Connect the battery - positive and negative.
  2. Connect the solar panels - positive and negative.
  3. Connect the consuming load - positive and negative.

When uninstalling, the same steps must be followed in reverse order. If this is done in a different order, the BlueSolar PWM charge controller may be damaged.

It should be borne in mind:

  • The battery must be charged in order for the BlueSolar PWM charge controller to recognise the battery type.
  • The battery cable should be as short as possible to reduce losses.
  • This regulator is only suitable for lead-acid and LiFePO4 batteries.
  • The BlueSolar PWM charge controller is only suitable for regulating solar panels. No other load source can be connected.

The following image shows the elements of the screen:

BlueSolar Victron PWM-LCD and USB BlueSolar Victron PWM-LCD and USB controller screen image

Monitoring and configuration

  • Start-up display: When the battery is connected, the display shows the solar charger model and system voltage recognised by the solar charger.
    • Code 110 is for BlueSolar PWM charge controller - LCD - USB 12V|10A
    • Code 210 is for BlueSolar PWM charge controller - LCD - USB 24V|10A
  • Main display: battery voltage, battery charge status, and amount of charge and discharge.
    • Press the MENU button for several seconds until the display flashes and you access different screens to make modifications:
      • Battery type.
      • Low voltage disconnection.
        • Factory setting is 11.2V
      • Low voltage reconnection
        • The factory setting is 12.6V battery.
      • Charge current display: PV current to battery and battery charge status.
      • Adjustment of the output of load consumers.
        • Factory setting is 24h (charging output always on).
      • Adjustment of the output of load consumers.
      • Activation level.
      • Delayed activation.
      • Adjustment of the short-circuit protection.
      • Discharge current display.
      • USB voltage display.
      • Internal temperature of the controller.

Datasheet and manual for BlueSolar Victron PWM-LCD and USB 12/24V-10A Controller - SCC010010050

See the data sheet of the BlueSolar Victron PWM-LCD and USB 12/24V-10A Controller - SCC010010050

View the manual for the BlueSolar Victron PWM-LCD and USB 12/24V-10A Controller - SCC010010050

Weight and dimensions

Weight 1 kg
Dimensions 9,6 × 19,6 × 3,6 cm

User feedback

Reviews

There are no reviews yet.

Be the first to review "BlueSolar Victron PWM-LCD and USB 12/24V-10A controller - SCC010010050"

Delivery deadlines

At FVComponentes.com we have stock of the references with the highest turnover, however our catalogue is so wide and economical because we work with many of the references on request. This means that the usual delivery time of 2-4 working days can be extended to 1-2 weeks + subsequent shipment by us. Thanks to this, we can offer very competitive and attractive prices to our customers that are difficult to match. If you wish, you can write to us via the chat on the website, call us at 968 97 83 01 or write to us at comercial@fvcomponentes.com to check if we have stock or the delivery time of the component you wish to purchase before finalising your order.