Energy meter Victron EM540 3 phase - max 65A/phase - REL200100100100

120,88€

TAXES INC.

Display: LCD
Phases: 3
Maximum rated current: 65 A per phase
Update rate: 100 ms

Producto disponible para la venta
Finance your purchase with Cetelem
Reference: REL200100100 Categories: , ,

Product information

Features of the Victron EM540 3 phase energy meter - max 65A/phase - REL200100100

The Victron EM540 3 phase energy meter - max 65A/phase - REL200100100 is a standard device for measuring the power and energy of an application. three-phasefor example in the distribution box or to measure the output of a PV inverter, an AC generator or an inverter or inverter/charger.

The EM540  can be configured with four different functions in one GX device, such as the Victron Cerbo GX MK2 Monitoring - BPP900451100:

  1. As a network counter and control input to an ESS system.
  2. To measure the output of a PV inverter.
  3. To measure the output of an AC generator.
  4. As an AC meter to measure the output of an inverter or inverter/charger.

It offers two options for connection to a GX device:

  1. A wired connection, using the RS485 to USB interface with a 1.8 m or 5 m cable length.
  2. A wireless connection via our Zigbee to USB converters y Zigbee to RS485.

Choose between RS485 or Ethernet connection:

The Ethernet mode will be more advantageous in installations where an Ethernet network is available. Instead of running an RS485 cable between the main AC distribution panel and the storage system, the existing Ethernet can be used. The disadvantage is that this is dependent on the network functioning correctly; in case of problems, the storage system will go into standby mode: passthrough.
EM24, EM3XX, EM5XX and ABB meters use vector registration for energy metering. This is the preferred method in countries such as Germany and Austria, and almost everywhere else. All other meters use the arithmetic register. See question P8 in the Victron energy meter manuals for more information about the differences in energy metering.

Datasheet Victron EM540 3 phase energy meter - max 65A/phase - REL200100100100

View Victron EM540 3 phase power meter guide - max 65A/phase - REL200100100

Additional information

Weight 1 kg
Dimensions 10 Ă— 5 Ă— 5 cm

Product reviews

Reviews

There are no reviews yet.

Be the first to review “Medidor de energĂ­a Victron EM540 3 fases – max 65A/phase – REL200100100”

Delivery deadlines

At FVComponents.com we have stock of the references with the highest turnover, however our catalogue is so wide and economical because we work with many of the references on request. This means that the usual delivery time of 2-4 working days can be extended to 1-2 weeks + subsequent shipment by us. Thanks to this, we can offer very competitive and attractive prices to our customers that are difficult to match. If you wish, you can write to us via the chat on the website, call us at 968 97 83 01 or write to us at [email protected] to check if we have stock or the delivery time of the component you wish to purchase before finalising your order.