Pytes Battery BCU Module HV48100 BCU (Battery Control Unit)

901,33

TAXES INC.

Essential for the operation of the BMU modules (Battery) HV48100

  • Controller operating voltage: 200 V ~ 870 V
  • Self-consumption of energy: 7.56 W
  • Communication: CAN, RS485, dry contact, WiFi
- +
Product available for sale
Finance your purchase with Cetelem
Reference: HV48100BCU Categories: ,

Details of the Pytes Battery BCU Module HV48100 BCU (Battery Control Unit)

Pytes Battery BCU Module HV48100 BCU (Battery Control Unit)

The HV48100 BCU Module is the central control unit of the HV48100 high voltage storage system, designed to manage, coordinate and monitor the operation of the HV48100 high voltage storage system. battery modules (BMU) in photovoltaic installations, hybrid systems and back-up power applications, both residential, commercial and industrial.

This component is essential for the correct operation of the battery system, as it coordinates the communication, safety and performance of all connected battery modules.

The BCU acts as the brain of the system, ensuring stable, safe and efficient operation by collecting information, implementing the safety logic of the system, organising the operation of the BMU modules and communicating with the inverter for stable, efficient and safe charging/discharging.

Main features of the BCU Module HV48100

Control, coordination and security

In a high-voltage modular system, such as the HV48100, it is essential to have a control unit that synchronises the behaviour of all battery modules and ensures that the system operates within safe parameters.

The BCU HV48100 takes care of very important functions such as:

  • Supervise and monitor the overall status of the system to operate efficiently and correctly.
  • Manage the operation of battery charging and discharging, coordinating the communication of all BMUs so that energy is delivered in a stable and protected manner.
  • Activate system protections
  • Transmitting information to the inverter or monitoring system

Thanks to this centralised management, the system operates in a synchronised and balanced manner, optimising the overall performance of the energy storage.

Monitoring and advanced security

This BCU continuously monitors total voltage, charge and discharge current, temperature, operating status, and alarms and events, both for the system and for each battery module.

If unwanted conditions such as overload/over-discharge or abnormal operating situations are detected, the BCU activates protection mechanisms to prevent damage to the batteries or the installation. This ensures the safety of both the system and the connected equipment.

Efficient operation

The BCU has a control voltage range of 200 V to 870 V and a contained self-consumption (self-consumption) of 7.56 W, which contributes to the overall efficiency of the energy storage. This is especially important in installations where the system is active for many hours.

Effective and reliable management

In high-voltage storage systems, such as the HV48100, coordination between battery modules is critical.

The Pytes HV48100 BCU ensures accurate, safe and optimised system management and helps to extend the lifetime of the HV48100 BMU (battery) modules. It also improves energy stability.

Consequently, this unit becomes an indispensable component in any Pytes HV48100 battery-based installation.

Modular design and cabinet integration

The HV48100 BCU is prepared for installation in the Pytes 19″ Rack Cabinet, This makes it easy to integrate with HV48100 BMU modules (batteries).
Its compact and professional design allows for a tidy, safe and easy-to-maintain installation.

In addition, the front layout provides easy access to indicators and communication connections.

With dimensions of 484 × 510 × 140 mm and a weight of 13.3 kg, it reflects a solid unit ready for structured mounting.

Main advantages of the Pytes Battery BCU Module HV48100 BCU (Battery Control Unit)

The main advantages of this BCU are the following:

  • Central control unit for HV48100 systems
  • Intelligent and synchronised management of BMU modules (batteries) HV48100
  • Advanced system protection
  • Continuous monitoring of electrical parameters
  • Installation in its own cabinet, the Pytes 19″ Rack Cabinet for HV48100

Technical information on the Pytes Battery BCU Module HV48100 BCU (Battery Control Unit)

BCU Module HV48100 Datasheet

HV48100 BCU Module Manual

Weight and dimensions

Weight 13,3 kg
Dimensions 51 × 48,4 × 14 cm

User feedback

Delivery deadlines

At FVComponentes.com we have stock of the references with the highest turnover, however our catalogue is so wide and economical because we work with many of the references on request. This means that the usual delivery time of 2-4 working days can be extended to 1-2 weeks + subsequent shipment by us. Thanks to this, we can offer very competitive and attractive prices to our customers that are difficult to match. If you wish, you can write to us via the chat on the website, call us at 968 97 83 01 or write to us at [email protected] to check if we have stock or the delivery time of the component you wish to purchase before finalising your order.