Maxge Alpha+ 2P, 25A, C-curve, 6kA - EPB63ME2C25
2,43€
TAXES INC.
- Configuration: 2-pole
- Operating voltage: 415V AC
- Rated current: 25 amps
- Breaking capacity: 6kA
- International standard EN/IEC60898-1
- Local status signalling
- Window for circuit marker
- Dimensions: 36mm (18mm per pole)
- Terminal connection for copper cables: 16mm² in flexible cable and 25mm² in rigid cable
- Insulation voltage (Ui) 500VA
- Pollution degree 3
- Impulse voltage (Uimp) 4kV
- Double insulation class 2
- Suitable for sectioning
- Working temperature: from -5ºC to + 40ºC.
- Non-accessoriable (except padlockable)
Product available for sale
Finance your purchase with Cetelem
Reference:
EPB63ME2C25
Categories: Circuit breakers, Electrical equipment
Details of the Maxge Alpha+ 2P, 25A, C-curve, 6kA - EPB63ME2C25
Maxge Alpha+ 2P, 25A, C-curve, 6kA - EPB63ME2C25
The Maxge Alpha+ 2P, 25A circuit breaker is a magneto-thermal circuit breaker designed to protect single-phase circuits against overloads and short circuits.
It offers a safe and reliable solution for electrical installations where medium and high loads are handled.
Thanks to its two-pole configuration (2P), its rated current of 25 A, tripping curve C and breaking capacity of 6 kA, it is a device widely used in homes.
It is also used in commercial premises and tertiary applications requiring robust protection.
This circuit breaker integrates thermal protection and magnetic protection in a single unit, acting automatically when an electrical anomaly occurs.
This prevents damage to cabling and connected equipment, and reduces the risk of breakdown or fire.
Main features of the Maxge Alpha+ 2P, 25A circuit breaker
Complete phase and neutral protection
Being from 2-pole (2P), This circuit breaker protects and disconnects the phase and neutral at the same time. This ensures that the circuit is completely isolated when the circuit breaker is manually tripped or switched off.
It therefore increases safety during maintenance or overhaul work on the control panel.
This type of protection is particularly recommended in single-phase installations, lighting circuits, specific sockets and socket lines with moderate consumption. Also in auxiliary and control circuits, and installations where a total circuit cut-off is required.
Demanding circuits
With a 25 ampere rated current, This circuit breaker is designed for lines with higher consumption than standard 16 A or 20 A circuits.
It is commonly found protecting heavy-duty sockets and lines dedicated to powerful appliances.
In addition, it is used in small air-conditioning units and circuits with several receivers operating simultaneously.
Provided that the installation is correctly dimensioned (adequate cable cross-section and additional protections)., The circuit breaker ensures stable, safe operation without unnecessary outages.
Stability without nuisance tripping
The firing curve C allows the circuit breaker to withstand moderate current peaks, such as those that occur when switching on certain electrical appliances, without causing unnecessary tripping.
This means fewer unplanned outages, greater convenience of use, and good protection against real overloads and short circuits.
Therefore, the C-curve is one of the most commonly used curves in general installations.
High resistance
Your 6 kA breaking capacity means that this circuit breaker is capable of safely interrupting short-circuit currents of up to 6,000 amperes without damage or loss of protective properties.
This level of breaking capacity is more than sufficient for homes, commercial premises, secondary switchboards and circuits far from the transformation point.
In other words, this circuit breaker provides a reliable level of protection for everyday use.
Quick installation and practical design
The Maxge Alpha+ 2P, 25A is designed for DIN rail mounting. So it is quick and easy to install in any standard electrical panel.
Your compact 36 mm wide design (18 mm per pole), helps to optimise the space available in the frame and features window for circuit marker y a visual status signalling (on/off), The circuit it protects can be easily identified.
In addition, it has some terminals that are prepared for cables suitable for this current (16mm² in flexible cable and 25mm² in rigid cable).
This ensures firm and secure connections.
Maxge Alpha+ 2P, 25A, C-curve, 6kA - EPB63ME2C25 - Operation and Applications
This circuit breaker protects the circuit by means of two complementary systems:
- Thermal protection (overload): acts when the current exceeds safe values for a prolonged period of time, preventing excessive heating of the conductors and possible damage to equipment or risk of fire.
- Magnetic protection (short circuit): responds almost instantaneously to very high currents, cutting off the supply and protecting the installation against serious faults.
It is ideal for use in residential switchboards, small shops and offices, high consumption socket circuits, and specific protection of demanding single-phase lines.
Main advantages of the Maxge Alpha+ 2P, 25A circuit breaker
This circuit breaker has the following advantages:
- Complete phase and neutral protection.
- It has 25 A, ideal for single-phase circuits with higher demand.
- Balanced and versatile C-curve.
- 6 kA breaking capacity, suitable for domestic and commercial use.
- Easy DIN rail installation and simple maintenance.
- Compact, robust and reliable design.
- Compliance with international quality norms and standards.
Technical information about Maxge Alpha+ 2P, 25A, C-curve 6kA - EPB63ME2C25
Data sheet Maxge Alpha+ 2P, 25A, Magnetotermico Maxge Alpha+ 2P, 25A
Weight and dimensions
| Weight | 0,2 kg |
|---|---|
| Dimensions | 6,66 × 3,6 × 7,8 cm |