{"id":36137,"date":"2026-01-24T09:49:08","date_gmt":"2026-01-24T08:49:08","guid":{"rendered":"https:\/\/fvcomponentes.com\/?post_type=product&#038;p=36137"},"modified":"2026-02-09T15:01:17","modified_gmt":"2026-02-09T14:01:17","slug":"magnetotermico-maxge-alpha-4p-63a-curva-c-10ka-epb63h4c63","status":"publish","type":"product","link":"https:\/\/fvcomponentes.com\/en\/producto\/magnetotermico-maxge-alpha-4p-63a-curva-c-10ka-epb63h4c63\/","title":{"rendered":"Maxge Alpha+ 4P, 63A, C-curve, 10kA - EPB63H4C63"},"content":{"rendered":"<h2>Maxge Alpha+ 4P, 63A, C-curve, 10kA - EPB63H4C63<\/h2>\n<p>The Maxge Alpha+ 4P, 63A circuit breaker is a magneto-thermal circuit breaker designed for the comprehensive protection of three-phase electrical installations with neutral (3 phases + neutral) against overloads and short-circuits.<br \/>\nIt is a robust, reliable, versatile and resistant switch that guarantees effective and safe protection.<\/p>\n<p>With a rated current of 63 A, tripping curve C and a breaking capacity of 10 kA, this circuit-breaker is aimed at applications where a high level of safety is required. It also provides reliable fault response and stable operation in distribution switchboards.<br \/>\nIt is widely used both in homes with high demand and in commercial or industrial installations.<\/p>\n<p>In addition, it combines thermal and magnetic protection in a single device, making it possible to cut off the supply when something goes wrong and prevent damage to the installation, connected equipment or even greater risks.<\/p>\n<h2>Main features of the Maxge Alpha+ 4P, 63A circuit breaker<\/h2>\n<h3>Complete phase and neutral protection<\/h3>\n<p>This circuit breaker is made of <strong>4-pole (4P)<\/strong>. It therefore simultaneously protects all three phases and the neutral conductor.<\/p>\n<p>This configuration is essential in three-phase electrical panels, as it ensures total isolation of the circuit when the device is activated, preventing residual voltages from remaining in any of the conductors.<br \/>\nThis increases personal safety, protects the installation and reduces risks during maintenance or intervention.<\/p>\n<p>The 4P format is widely used in main switchboards, distribution boards, three-phase machinery with neutral, air-conditioning systems, pumps, fans, small and medium-sized motors. It is also used in circuits where a uniform and simultaneous cut-off of all poles is required.<\/p>\n<p>In industrial, tertiary applications or in certain distribution configurations, the 4P cut-off provides increased safety during maintenance work.<br \/>\nIt also allows the complete isolation of the circuit and better control and isolation in three-phase installations with neutral.<\/p>\n<p>In short: more safety and fewer scares when work has to be carried out on the switchboard or when a fault occurs.<\/p>\n<h3>Adequate capacity for demanding loads<\/h3>\n<p>With a <strong>rated current 63 amps<\/strong>, This circuit breaker is designed for circuits with high consumption, such as main lines.<br \/>\nIt is also suitable for circuits that move several pieces of equipment at the same time or shunts where significant and continuous loads are handled.<\/p>\n<p>This capacity makes it suitable for powering equipment with higher power consumption, or several receivers operating simultaneously.<br \/>\nHowever, the installation must be correctly dimensioned in terms of conductor cross-section, earth leakage protection and the rest of the switchboard elements.<\/p>\n<p>In addition, its <strong>operating voltage up to 415\/240 V AC<\/strong> The new system is suitable for use in most standard or common three-phase installations.<\/p>\n<h3>High short-circuit resistance<\/h3>\n<p>The <strong>cutting power of<\/strong> this circuit breaker is made of <strong>10 kA (10,000 amps)<\/strong>. It is capable of breaking strong short circuits without damage or compromising the integrity of the electrical system.<\/p>\n<p>This level of protection means that the circuit breaker responds even in difficult situations and prevents serious damage to the installation, especially in switchboards close to transformers, installations with a lot of available power and networks with low line impedance.<\/p>\n<p>This high cutting power provides extra safety and reliability, making the Maxge Alpha+ a highly recommended option in demanding environments.<\/p>\n<h3>Sensitivity and tolerance to peak loads<\/h3>\n<p>The Maxge Alpha+ 4P, 63A circuit-breaker incorporates a <strong>firing curve C<\/strong>. It is designed to tolerate moderate current peaks without causing untimely tripping.<\/p>\n<p>The C-curve provides an optimum balance between sensitivity and stability, maintaining effective protection against dangerous overcurrents without affecting the normal operation of the installation.<\/p>\n<p>This reduces nuisance shots.<br \/>\nIn addition, the installation is more stable and good protection against real overloads and short circuits is maintained.<\/p>\n<p>It is therefore suitable for circuits with general and mixed loads, small to medium-sized motors, starters, transformers, ventilation, pumps, air conditioning, electronic equipment and power supplies, lighting and three-phase sockets, and equipment that may have start-up peaks (without being extreme).<\/p>\n<h3>Installation and design<\/h3>\n<p>The Maxge Alpha+ 4P, 63A is designed for <strong>DIN rail mounting<\/strong>, This facilitates quick and tidy installation on any standard frame.<\/p>\n<p>Your <strong>terminals<\/strong> are prepared to accept conductors of suitable cross-section for this current rating <strong>(25 mm\u00b2 in flexible cable and 35 mm\u00b2 in rigid cable)<\/strong>. This ensures firm and secure connections without overheating or false contacts.<\/p>\n<p>In addition, it has a <strong>compact 72 mm wide design<\/strong> (18 mm per pole), and it features <strong>window for circuit marker<\/strong> and a <strong>visual status signalling (on\/off), <\/strong>facilitating the identification of the circuit it protects.<br \/>\nThus, it provides rapid diagnosis and maintenance.<\/p>\n<h2>Maxge Alpha+ 4P, 63A, C-curve, 10kA - EPB63H4C63<\/h2>\n<p>This circuit breaker acts as a fundamental protection element in electrical distribution because it combines thermal and magnetic protection in a single mechanism:<\/p>\n<ul>\n<li><strong>Thermal protection (overload):<\/strong> acts if there is an overload for a prolonged period of time, preventing the cables from overheating.<\/li>\n<li><strong>Magnetic protection (short circuit):<\/strong> acts quickly when there is a short circuit, cutting off the supply almost instantly.<\/li>\n<\/ul>\n<p>It is ideal for use in main or secondary switchboards in industrial, commercial or residential buildings with demanding loads. It thus provides robust and effective protection.<\/p>\n<p>Its 4-pole design covers both three-phase supply and neutral conductor protection, which is crucial for balanced systems or with single-phase loads connected in combination.<\/p>\n<h2>Main advantages of Maxge Alpha+ 4P, 63A<\/h2>\n<p>The advantages of this circuit breaker are as follows:<\/p>\n<ul>\n<li>Complete protection in three-phase installations with neutral.<\/li>\n<li>63 A capacity for demanding lines.<\/li>\n<li>10 kA breaking capacity, ideal for higher risk environments.<\/li>\n<li>Balanced C-curve, no unnecessary tripping.<\/li>\n<li>Easy to install and maintain.<\/li>\n<li>Robust and reliable construction.<\/li>\n<\/ul>\n<h2>Technical information about the Maxge Alpha+ 4P, 63A, C-curve 10kA - EPB63H4C63<\/h2>\n<p><a href=\"https:\/\/fvcomponentes.com\/wp-content\/uploads\/2026\/02\/es_fichas-tecnicas_EPB63H-20251104.pdf\" target=\"_blank\" rel=\"noopener\">Maxge Alpha+ 4P, 63A circuit breaker technical sheet<\/a><\/p>\n<p><a href=\"https:\/\/fvcomponentes.com\/wp-content\/uploads\/2026\/02\/es_fichas-tecnicas_Ficha_tecnica_EPB63H.pdf\" target=\"_blank\" rel=\"noopener\">Maxge Alpha+ 4P, 63A circuit breaker technical data<\/a><\/p>","protected":false},"excerpt":{"rendered":"<ul>\n<li>Number of poles: 4-pole (3 phases + neutral)<\/li>\n<li>Rated current (In): 63 Amps<\/li>\n<li>Operating voltage: 415\/240V AC<\/li>\n<li>International standard EN\/IEC60898-1<\/li>\n<li>Local status signalling<\/li>\n<li>Window for circuit marker<\/li>\n<li>Terminal connection for copper cables: 25 mm\u00b2 (flexible) \/ 35 mm\u00b2 (rigid)<\/li>\n<li>Dimensions: 72 mm wide (18 mm per pole)<\/li>\n<li>Allows attachment of accessories and control gear<\/li>\n<li>Isolation voltage (Ui): 500VA<\/li>\n<li>Pollution degree 3<\/li>\n<li>Impulse voltage (Uimp): 4kV<\/li>\n<li>Double insulation class 2<\/li>\n<li>Suitable for sectioning<\/li>\n<li>Working temperature: -5 \u00b0C to +40 \u00b0C<\/li>\n<\/ul>","protected":false},"featured_media":36637,"comment_status":"closed","ping_status":"closed","template":"","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","ast-disable-related-posts":"","theme-transparent-header-meta":"default","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-opacity":"","overlay-gradient":""}}},"pwb-brand":[1018],"product_brand":[],"product_cat":[990,410],"product_tag":[],"class_list":{"0":"post-36137","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"pwb-brand-maxge","7":"product_cat-magnetotermicos","8":"product_cat-material-electrico","9":"desktop-align-left","10":"tablet-align-left","11":"mobile-align-left","12":"ast-product-gallery-layout-horizontal-slider","13":"ast-product-gallery-with-no-image","14":"ast-product-tabs-layout-horizontal","16":"first","17":"instock","18":"taxable","19":"shipping-taxable","20":"purchasable","21":"product-type-simple"},"wcpa_form_fields":null,"brands":[{"id":1018,"name":"Maxge Electrical Protections","slug":"maxge"}],"_links":{"self":[{"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/product\/36137","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/comments?post=36137"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/media\/36637"}],"wp:attachment":[{"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/media?parent=36137"}],"wp:term":[{"taxonomy":"pwb-brand","embeddable":true,"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/pwb-brand?post=36137"},{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/product_brand?post=36137"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/product_cat?post=36137"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/fvcomponentes.com\/en\/wp-json\/wp\/v2\/product_tag?post=36137"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}